CyberPower CA50A48V2 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Non CyberPower CA50A48V2. CyberPower CA50A48V2 User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 1
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
User’s Manual
for CS36A12V2
Bundled Kit
(CA50A48V2 + CS36D12V)
The CS36A12V2 provides increased flexibility and cost effectiveness by separating the power supply
unit (CA50A48V2) from the battery back up unit (CS36D12V). The power supply plugs into a 110/120Vac
outlet. It converts the power to 48Vdc, which is then fed through a power cord to the battery back up unit.
The battery back up unit feeds 12Vdc to the ONT.
IMPORTANT SAFETY WARNINGS
(SAVE THESE INSTRUCTIONS)
This manual contains important instructions regarding the installation and operation of this device.
Read this manual thoroughly before attempting to unpack, install or operate this device
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity
controlled indoor area free of conductive contaminants. (Please see specifications for
acceptable temperature and humidity range.)
CAUTION! T
Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries
according to the instructions.
o reduce the risk of electric shock, do not remove the cover except to service the
battery. No user serviceable parts are inside except the batter
CAUTION!
This unit must be wall mounted. Do not use the unit unless it is mounted correctly.CAUTION!
y.
OVERVIEW (CA50A48V2)
OVERVIEW (CS36D12V)
INTRODUCTION
SYSTEM BLOCK DIAGRAM
The UPS battery charges when it is connected to utility power. The battery charges
fully during the first 24 hours of normal operation. Do not expect full battery run
capability during this initial charge period.
CA50A48V2
Power Supply
CS36D12V
Battery Back Up
ONT
110/120Vac 12Vdc48Vdc
INSTALLATION
Carefully follow these instructions during the installation of this device:
1.) Carry out the installation in a safe area that is free of excessive dust and has adequate airflow.
2.) Screws must be appropriate for total weight of the UPS unit and the mounting surface material.
3.) Do not operate the UPS where the temperature and humidity are outside the specified limits.
(Refer to specifications in this manual.)
Step 1:
a. Open the power connector
compartment cover.
Step 1:
a. Press the battery cover release latch (A) and
slide the cover to remove.
b. Remove the 9 pin connector compartment
cover by pulling outward.
Step 3:
a. Remove protective shipping terminal covers from
the battery if necessary.
b. Connect the battery cable leads to the appropriate
terminals; red to postive, black to negative.
c. Insert the battery into the battery compartment.
d. Install the 9 position IDC connector to the unit (see Fig.1).
Step 4:
a. Install both power and interconnection cables to
the 9 position IDC connector.
(See case for the pin assignments.)
b. Close the 9 pin connector compartment cover.
c. Close the battery cover.
Step 2:
a. Insert the power and interconnection cables
into the back cable channel. Feed the
cable end into the 9 pin connector
compartment.
b. Securely mount the unit on the wall with 2
mounting screws.
Step 2:
a. Install output power cable to the 2
position IDC connector (red wire
to positive, black wire to negative).
b. Thread the power cable along the
back of the power connector cover.
Wrap the power cable around the
strain relief lip. Insert the cable
through one of the cable slots to
exit the compartment.
c. Insert the power cable into one of
the cable channels on the back of
the unit.
Step 3:
a. Place screw in keyhole screw slot
and tighten half way.
b. Slide unit so that the screw rests
against the narrow end of the slot.
c. Place second screw into the screw
hole and tighten securely.
d. Tighten keyhole slot screw securely.
e. Close the power connector
cpmpartment cover.
CA50A48V2 Installation Guide
CS36D12V Installation Guide
A
a
b
a
c
c
b
NOTE : Please use appropriate size screws to mount the CA50A48V2 on the wall.
NOTE : Recommended screw size: Self-tapping screw M4x20L (Truss head)
NOTE : Please use appropriate size screws to mount the CS36D12V on the wall.
NOTE : Recommended screw size: Self-tapping screw M4x20L (Truss head)
CA50A48V2 Front CA50A48V2 Back
CS36D12V Front
CS36D12V Back
1
2
3
4
5
6
7
8
1
2
5
4
6
3
7
8
9
1. Power Connector
Compartment Cover
2. Strain Relief Lip
3. 2 Pin IDC Connector
4. Power LED Indicator
5. Screw Hole
6. Keyhole Screw Slot
7. Cable Channel
8. Input Power Cord (8 ft.)
1. Battery Compartment Cover
2. Control Buttons
(Alarm Silence / Battery
Emergency Use)
3. LED Indicators
(Auxiliary Power Source /
Replace Battery / Battery
Power / System Status)
4. Battery Compartment
5. 9 Pin Conductor Compartmemt
Cover
6. Battery Release Latch
7. Interconnection & Power Cable
Channel
8. Keyhole Screw Slot
9. Pass Through Hole for
Interconnection & Power Cable
Fig.1
Vin +
Vin -
Vout +
Vout -
Signal Return
On Battery
Replace Battery
Missing Battery
Low Battery
Status LED, Alarm & Communication Signals
Battery Type
Auxiliary Power Connection (AUX)
Connection point for customer-supplied DC input voltage (12Vdc). At 45% remaining capacity, the
CS36D12V switches from internal battery to external source. The auxiliary power source supplies power
to the load (ONT) in the event of 48V input voltage failure and a battery capacity of <45%.
Maintenance Mode
FCC NOTICE:
K01-3612000-03
Specification
Input
Voltage Range
Frequency Range
Output
Output Voltage (Normal)
Output Voltage (Battery Mode)
Output Power Max
Ripple
Connector Type
Battery
Battery Type
Numbers of Battery
Auxiliary Input Power
Warning Diagnostics
Indicators
Alarm
Management
Communication Interface
Physical
Maximum Dimensions (L*W*D)
Weight (lb)
Environment
Operating Temperature
Operating Humidity
Max Operating Elevation
Max Storage Elevation
Storage Temperature
120Vac 48Vdc
50 / 60Hz
48Vdc 12Vdc
10.5 ~ 20Vdc
48W 34W
less than 200 mV
Insulation Displacement Connector (IDC)
Sealed, Maintenance Free Lead-Acid Battery
7.2Ah / 12V
12Vdc / 1.3mm COAX Power Jack
AC Power Auxiliary Power Source /
Replace Battery /
Battery / System
AC Fail / Replace Battery
Replace Battery /
Low Battery
Signal Retun / On Battery /
Replace Battery / Missing
Battery / Low Battery
5.94 x 2.65 x 1.56 in 6.89 x 6.75 x 3.47 in
0.77lb 1.51lb
-4
o
F ~ +115
o
F (-20
o
C ~ +46
o
C)
0 - 95% noncondensing within enclosure
10,000ft (3,000m)
50,000ft (15,000m)
-4
o
F ~ +113
o
F (-20
o
C ~ +45
o
C)
Model CA50A48V2 CS36D12V
Operation Guide
LED Indicators
Press and hold the button for 1 second to silence the audible alarm.
Press and hold the button to activate emergency battery capacity.
Indicates that an external power source with adequate voltage
(12Vdc) is connected to the CS36D12V.
Battery replacement required. Alarm will beep once every 15 minutes.
Indicates the battery is supplying the power. At 45% battery capacity,
this LED will flash and then alarm will beep 4 times per minute.
Indicates normal mode of operation.
Blue
Blue
Green
Red
Green
Green
Alarm Silence Button
Battery Emergency
Use Button
Auxiliary Power Source
Replace Battery
Battery Power
System Status
Indicator Color Condition
1/2 sec beep
every 15 min
None, only
ON sees
alarm
1/2 sec beep
every 15 sec
All communication
signals in Low state
Open
Open
Open
Open
Condition normal; AC power load, charges battery.
Battery is connected and in good condition.
48V input failure or loose connection between
power supply and battery board; battery is supplying
the power.
Every 45 days, the unit will automatically initiate a
battery test. The test lasts 16 hours. if the battery
needs to be replaced, an alarm signal will be sent to
the Central Office.
Approximately 6 seconds after battery removal, the
system initiates battery detection routine. Upon
failure, an alarm signal will be sent.
When battery capacity is < 45% (approximately
12Vdc), unit signals low battery.
System LED On
Battery LED On
Replace Battery
LED On
Battery LED Flash
Normal
ON Battery
Replace Battery
Battery Missing
Low Battery
Condition Status LED Alarm Interface Description
A
CS36D12V Battery Replacement
c
Batteries are considered HAZARDOUS WASTE and must be disposed of properly.
Most retailers that sell batteries collect used batteries for recycling.
Fig.2
Start-Up: Plug the CA50A48V2 power supply into AC power. The unit is now ready to be placed into
service. The CS36D12V has four LED indicators and two control buttons. The table below
lists the functions of each.
The battery is a standard sealed lead acid battery rated at 12Vdc / 7.2Ah. If required, the battery may be
replaced with an approved 12Vdc / 7Ah battery.
Maintenance mode determines remaining useful battery life. During the 16 hour test, the battery is
discharge to determine its state. The unit measures the rate of change in the battery charge. If the rate of
discharge is excessive, the battery replacement indicator is activated.
The CS36D12V enters the maintenance mode approximately once every 45 days.
In the event that the CS36D12V is in the maintenance mode and an AC failure occurs, maintenance
mode will cease and the CS36D12V will supply the power to the load.
Step 1:
a. Press battery cover catch (A) and slide the cover to the left
to remove.
b. Remove the battery connector (see Fig.2).
c. Remove the battery strain release latch to remove battery.
Step 2:
a. Replace battery cable on the new battery.
b. Place the new battery into battery compartment.
c. Close the battery cover.
This equipment has been tested and found to comply with the limit for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with these instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: (1) Reorient or relocate the receiving antenna.
(2) Increase the separation between the equipment and receiver. (3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. (4) Consult the dealer or an
experienced radio/TV technician for help.
CAUTION: Signal cables must be used with this device to ensure compliance with Class B FCC limits.
CAUTION: Any changes or modifications could void the authority granted by the FCC to operate this equipment.
Vue de la page 0
1

Résumé du contenu

Page 1 - User’s Manual

User’s Manualfor CS36A12V2Bundled Kit(CA50A48V2 + CS36D12V)The CS36A12V2 provides increased flexibility and cost effectiveness by separating the power

Commentaires sur ces manuels

Pas de commentaire